| Turn off machine and unplug
from socket.
Take off
the capsule cage & frothing attachment
+
or
Using tool
& capsule holder provided.
+
or 
Put these
items into a pint of water; include the capsule holder
but not the plastic tool, & add one cleaning tablet.
Soak for 1 hour.

Be careful
not to lose the following. Put these all in the solution.
Meanwhile
put 1 pint of water into water tank and add 30 mls of
Nilscale.
Plug in
machine, turn on power at plug only, for M300, Robot
café & l`expresso,
Which are
automatically descaling machines.
You will need to read your instruction manuals.
For all
other models turn on at machine.
Run machine
as if making coffee without capsule holder or cage in.
into a cup or suitable container run ½ a cup
through.
Run steam
side of machine on water not steam without frothing
attachment into a cup. Until cup is ½ full. Stop
this function.
Switch
off machine and leave for 15 minutes.
Repeat
this cycle (1/2 cup-1/2 cup leaving to stand for 15
minutes) until all solution has gone from water tank.
Wash water
tank with soapy water, rinse, and fill with clean fresh
water.
Take frothing
nozzle e.t.c. from cleaning fluid, wash in soapy water
and rinse.
Now you
are ready to put the capsule cage back into the machine.
Put this on top of the spring this way up.
Then put spring on top of capsule cage,
if this is blocked
you will need to clear with
, put o-ring
on top of capsule cage at thread.
replace
capsule cage using tool and capsule holder.
Then take
frothing nozzle, if end blocked clean with needle, not
this
tool, as it will make the hole to big.
Put onto
end of steam tube.
Start machine
again and run 2 cups of water through steam nozzle.
Then run
2 cups of water through the capsule cage.
Finished
,you will need to do this once a month.
To keep machine working
as new.
|